- 
                            Overview 
- 
                                Models 
- 
                                Case Study 
- 
                                FAQs 
- 
                                Related Resources 
- 
                                Related Services 
Overview
The lipophilicity of drugs plays an important role in pharmacology, pharmacokinetics, and toxicology. Hence, the study of the lipophilicity of test compounds is helpful in establishing the structure-activity relationship of drugs. In the early stage of drug development, the lipophilicity determination of the test compounds helps researchers find their druggability problems as early as possible and helps to study the ADMET properties of the compounds, which can reduce the failure rate of candidate drugs in the clinical research stage. WuXi AppTec DMPK used the classic Shake-Flask method, reversed phase high-performance liquid chromatography (RP-HPLC) method, and potentiometric titration method to determine the lipophilicity of the compounds, described by Log D and Log P.
Learn More
 
                                 
                        Models
- 
                                        Shake-Flask MethodTheoretical Concentration 67 μM Media 1-octanol; 100 mM phosphate buffer, pH 7.4 (routine), or other pHs Percentage of DMSO 0.67% Incubation Equilibration Time 1 h Equilibration Temperature Room temperature Sample Volume Required 20 μL of DMSO stock solution at 10 mM sample concentration Analytical Method LC-MS/MS Turnaround Time 3-5 working days RP-HPLC MethodTheoretical Concentration 400 μM Media 50 mM CH3COONH4 in water (pH 7.4);0.25% (v/v) 1-Octanol in methanol Sample Volume Required 30 μL of DMSO stock solution at 10 mM sample concentration Analytical Method HPLC-UV Turnaround Time 5 working days 
- 
                                        Test Method Description Data Deliverable Shake Flask Log D value obtained from 7 different pH values (the general buffer pH range from 1.8 to 12) Plot Log D vs pH curve to calculate Log P Log D vs pH (1.8 to 12) Log P Chromatography Log P value is calculated from the residence time of the compound on the column Log P Potentiometric Titration Measurement of pKa Calculate Log P by the pKa curve Log P 
Case Study
- 
                                            
                                                For compounds with Log P values within the range of -2~4, the conventional Shake-Flask method is the classic determination method and the gold standard. The characteristic of this method is fast and accurate. However, since the properties of the compounds studied became more and more complex, for example, the number of compounds with Log P >5 is dramatically increased, it is necessary to explore new method to determine the Log P values of new special or complex compounds. For high lipophilicity compounds (Log P >5), WuXi AppTec DMPK established a chromatographic method for the determination of high lipophilicity compounds, which can quickly and accurately obtain the Log P value of test compounds. Part of the validated data for some commercial compounds are shown below: - 
                                                                Linear fitting of the standard equation using Method 1 Figure 1 
- 
                                                                Linear fitting of the standard equation using Method 2 Figure 2 
 
- 
                                                            
FAQs
- 
                                        What is the main difference between Log D and Log P? - Log D: The degree of drug ionization in solution ranges from 0 to 100%, depending on the pKa of the compound and the pH of the aqueous phase; 
- Log P: All drugs in the solution are neutral molecules. 
 
- 
                                        Why is either too high or too low Log P not good for absorption? When oral drugs permeate through passive diffusion, it is generally considered that compounds of medium Log P (range 0~3) have the best gastrointestinal absorption. If Log P is too low, the passive diffusion permeation of the compound is low. However, if Log P is too high, the solubility of the compound is poor, and low solubility leads to poor absorption and bioavailability of the compound. 
- 
                                        For compounds with too high or too low lipophilicity, how can we get more accurate results when using the shake-flask method? - Compounds with high lipophilicity usually have non-specific absorption issues. For these compounds, low-bonding consumables can be used to replace ordinary consumables during the experiment. 
- For compounds with too high or too low lipophilicity, the instrumental response in the two-phase will be significantly different (or even no response in one phase). In terms of these cases, the solutions are that the incubation concentration can be appropriately increased, or the volume ratio of two phases and the dilution ratio of sample for two phases can be adjusted to improve the instrumental response of the compound in the lower distribution phase. 
 
- 
                                        What are the differences between different methods for the Log P determination? Methods for Log P determination Range(Log P value) Interference Speed Compound amount Reproducibility Predictability In silico method Wide - Fast - - ★ Shake flask method -2~4 Not applicable to compounds that tend to degrade; There is a strict requirement for purity Fairly Fast Small ★★ ★★★ RP-HPLC method 0~6 Mild, not sensitive to impurities Fast Small ★★★ ★★ Potentiometric titration method Fairly wide Limited by solubility Time-consuming Large ★★★ ★★★ ★indicates the grade 
Related Resources
- 
                                        
                                                Development of a High-throughput and Cost-effective Method for Experimental Polar Surface Area Measurement with Ultra-Performance Convergence Chromatography Tandem Mass SpectrometryPostersJul 24, 2025Learn More
- 
                                        
                                                Enhancing Permeability Through Exposed Polar Surface Area (EPSA) for Beyond Rule of Five (bRo5) Drug CandidatesArticlesApr 10, 2025Learn More
- 
                                        
                                                Rapid Determination of Lipophilicity: Exploration and Establishment of Reversed-Phase Liquid Chromatography (RPLC) MethodsPostersNov 05, 2024Learn More
- 
                                        
                                                Ensuring drug product integrity: The crucial role of stability testingBlogsOct 27, 2024Learn More
- 
                                        
                                                How to Evaluate Lipophilicity Rapidly? The Significance of Reversed-Phase Liquid Chromatography (RP-HPLC)BlogsDec 19, 2023Learn More
- 
                                        
                                                Rapid Determination of Lipophilicity: Establishment and Application of Reversed-Phase Liquid Chromatography (RP-HPLC)ArticlesNov 30, 2023Learn More
- 
                                        
                                                Focusing on PROTAC Permeability and Solubility Improving the Oral AvailabilityBlogsJul 07, 2023Learn More
- 
                                        
                                                Research on PROTAC Druggability: Solubility and PermeabilityArticlesJun 30, 2023Learn More
Stay Connected
Keep up with the latest news and insights.
 
        
         
    
 
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                             
                                         
                                         
                                         
                                        